IV – The Compact One.

Standard features

• For daily ventilation requirements and smoke extraction in case of fire F300 (300 °C/120 min.).
• Symmetrical impeller blades; 100% reversible with low noise emissions.
• IP55 motors, insulation class H (smoke extraction ver- sion); IP55 motors, insulation class F (CO ventilation), according to EN60034-5.
• 50/60 Hz version available.
• Tested maintenance switch optional.
• Housing from galvanised sheet steel.
• Tested according to EN 12101-3.
• CE certification by BSI.

Inquire Now   Technical Data  

*Click the button if you wish to view/download the Technical Data.
Categories: Car Park Fans, Industrial Fans. Tags: axial fan, car park fan, car park fans.
  • Description

Product Description

Who is Systemair?

Systemair Fan Testing,( Smoke Testing ) 

Systemair Car Park Smoke Testing

Systemair Spain

Related Products

  • wallmountedaxialfanADDED

    Wall Mounted Axial Fan

    systemairlogo

    Wall Mounted Axial Fan

    • 315mm to 1250mm diameter.
    • Volume flow from 0.4m3/s to 35m3/s.
    • Static pressure up to 400 Pa.
    • Mild steel construction with a high quality epoxy powder coating or hot dip galvanised.
    • Impellers have GRP blades or die-cast Aluminum adjustable blades.
    • IEC standard or smoke extract motors, single or two speed; with protection guard as an option.

    Motor

    Totally enclosed squirrel cage induction motor specially designed for minimum power consumption to cater for the desired fan characteristic. Motor is provided with the following features:

    • Class F insulation (Class H – optional).
    • Electricity Supply: Single/Three Phase.
    • IP 55 protection.

     

    *Click the button if you wish to view/download the Technical Data.
  • fiberglassblowerADDED

    MD-N750


    *Click the button if you wish to view/download the Technical Data.
  • centrifugalfanADDED

    PRF 250D4 IE2

    systemairlogo

    PRF 250D4 IE2

    • High efficient motor IE2
    • Speed-controllable via frequency converter
    • Integral cold conductor (PTC)
    • Standard motor outside the air stream
    • Temperature of transported air from -15°C – +70°C
    • Position of casing can be easily adapted
    • Single-flow impellers from PP with effective blade geometry
    • Low sound level
    • The powder painted pedestal is manufactured of galvanized steel
    • Perfect fitting accessories: connections, dampers, splinter protection
    • Easy to maintain and reliable

    The PRF fans size 160D2 are equipped with high efficient IE2 motors. The PRF fans have been developed especially for the exhaust of aggressive media. This is the right fan when corrosive gases, contaminated air or other aggressive components are part of the exhaust air. Typical applications are medical facilities, the food-, electrical-or chemical industry. Speed control is only possible by using a frequency converter. Motor protection is done by cold conductors (PTC), which have to be connected to an external motor protection device.

    The sintered casing is from UV-resistant PE and offers a variety of applications with its connectors from ø 125 – 250 mm. The casing can be easily adjusted through turning it (Standard position is LG270, see picture).

  • centrifugalfanbothADDED

    Centrifugal Fan

    systemairlogo
    Belt-Driven Centrifugal Cabinet Fan AW Series

    Systemair’s range of centrifugal fans offer the engineers the flexibility to choose the most suitable sizes and configurations to suit any site condition. With over 2000 variations of diameter, width and impeller type, specifications are virtually tailor-made to individual needs. We offer both single and double inlet forms and in three classes of construction to suit almost any applications.

    There is a choice of eight impeller types, providing optimum performance to meet any duty. Casings are made of mild steel, welded and many are of semi-universal construction allowing the discharge angle to be modified to suit customer’s requirements. Many additional features and ancillaries can be supplied on request, example; split casings, carbon steel and stainless steel impellers.

    Centrifugal Fans – Types of Blades

    There are many different types of Centrifugal Fans covering air volumes from 50 CFM to 60,000 CFM and from 0.1 inches water gauge to 60 inches water gauge. Each application requires a fan with different characteristics, whether it be the blade design, the width of the casing or even the method of drive. By way of a guide as to which is the best for certain projects, we list below information that might assist the potential user.

    Paddle Blades

    This type of fans is used for the conveying of dust, woods and paper refuse, cotton fly etc. Since the blade design prevents ‘Build up’ of waste materials, discharge velocities vary dependent upon what is being conveyed in the air- stream. Normally in the region of 1500-4000 feet per minute.

    Multivane or Forward Curved Blades

    Used for general ventilation purposes – not good for dust, etc. Limited pressure characteristics. Normal discharge velocities 1000-2500 feet per minute.

    Backward Curved or Backward Inclined Blades:

    Non-overloading power characteristic suitable for very light dust applications (e.g. clean side of dust collector) where a good efficiency is required. Used for high pressure ventilation systems or where the system resistance could fluctuate. Normal discharge velocities 1800-3000 feet per minute.

    High Pressure Blowers:

    As their name suggests, these fans are supplied where the requirement is for high velocities, e.g. Air curtains, refuse conveying, etc. Normal discharge velocities 3000-6000 feet per minute.

    Special Note:

    Since Forward Curved and Paddle Blade fans have overloading power characteristic it is important the selected static pressure is achieved. Any reduction in the requirement could easily overload the motor.